Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Arq. bras. oftalmol ; 86(1): 38-45, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403477

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were used, and checked the results. Methods: Scleral contact lens fittings in a private clinic setting were prospectively analyzed in a sequential, non-randomized, and non-comparative manner. All the patients underwent a complete ophthalmic examination and had an indication for scleral lens use (Zenlens, Alden Optical). Results: Scleral fit was analyzed in 80 eyes of 45 patients. Regarding diagnosis, 72% of the patients had keratoconus; 12%, radial keratotomy; 5%, post-refractive surgery ectasia; 5%, dry eye; and 3%, high myopia. In 66 (82.5%) of the 80 eyes studied, parameters were modified when the lenses were ordered. The reasons that led to the modifications were apical touch or decreased sagittal height, increased sagittal height, cylindrical over-refraction, poor visual acuity, lens flexure, peripheral touch, 360° edge compression, horizontal edge compression, and vertical edge compression. Conclusion: In this study, the use of Zenlens scleral lenses was shown to be a promising corrective treatment for patients requiring the use of scleral lenses. Although the study suggests a learning curve, as many adjustments were allowed, the lens could be customized according to the patients' needs. This increased the success rates of fitting and wearing, and consequently, use of the lens became a great option for the visual rehabilitation of patients.


RESUMO Objetivo: Avaliar o processo de adaptação de uma lente escleral que permite vários ajustes de parâmetros durante os testes e após o período inicial do seu uso; verificar quais os ajustes foram necessários, quais foram os mais utilizados, as suas indicações, a frequência com que estes recursos foram utilizados, e avaliar os resultados das mudanças realizadas. Métodos: A adaptação da lente de contato escleral foi analisada prospectivamente, de forma sequencial, não aleatória e não comparativa. Todos os pacientes foram submetidos a um exame oftalmológico completo e tinham indicação para o uso de lentes esclerais. Foi utilizada a lente Zenlens (Alden Optical). Resultados: Foi analisada a adaptação de lentes de contato esclerais em 80 olhos de 45 pacientes. Quanto ao diagnóstico, 72% tinham ceratocone, 12% tinham sido submetidos a ceratotomia radial, 5% tinham ectasia pós-cirurgia refrativa, 5% tinham olho seco, e 3%, alta miopia. Em 66 dos 80 olhos estudados (82,5%), os parâmetros foram modificados quando as lentes foram encomendadas. As razões foram: toque apical ou diminuição da altura sagital, aumento da altura sagital, sobre-refração cilíndrica, baixa acuidade visual, flexão da lente, toque periférico, compressão da borda em 360° e compressão da borda horizontal e/ou vertical. Conclusão: O uso de lentes esclerais Zenlens demonstrou ser uma forma de correção muito promissora para os pacientes que requerem o uso de lentes esclerais. Embora o estudo sugira uma curva de aprendizagem, é possível personalizar as lentes de acordo com as necessidades de cada pacientes. Este fato melhora a adaptação e aumenta a chance de sucesso do uso.

2.
Arq. bras. oftalmol ; 79(2): 82-84, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-782795

RESUMO

ABSTRACT Purpose: Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the present study was to evaluate the association between keratoconus evolution grade and topography pattern and the type and design of fitted contact lens. Methods: We performed a retrospective analysis of contact lenses fitted in a total of 185 patients with keratoconus (325 eyes). Keratoconus was classified as either grade I, II, III, or IV based on keratometry and cone morphology (nipple, oval, globus, or indeterminate) results. Results: A total of 325 eyes were evaluated in the present study. Of the 62 eyes classified as grade I, 66.1% were fitted with monocurve contact lenses. Of the 162 eyes classified as grade I and II, 51%, 30%, and 19% were fitted with adapted monocurve rigid gas-permeable contact lenses (RGPCL), bicurve lenses, and others lens types, respectively. Bicurve lenses were fitted in 52.1% and 62.2% of eyes classified as grade III and IV, respectively. Of the eyes classified as grade III and IV, monocurve and bicurve RGPCL were fitted in 26% and 55%, respectively. In eyes with oval keratoconus, 45%, 35%, and 20% were fitted with monocurve lenses, bicurve lenses, and other lens types, respectively. In eyes with round cones (nipple morphology), 55%, 30%, and 15% were fitted with bicurve lenses, monocurve lenses, and other lens types, respectively. Conclusion: Monocurve RGPCL were most frequently fitted in patients with mild to moderate keratoconus and oval cones morphology, while bicurve lenses were more frequently fitted in patients with severe and advanced keratoconus. This was probably because bicurve lenses are more appropriate for round cones due to increased corneal asphericity.


RESUMO Objetivo: O ceratocone é uma ectasia corneana bilateral e assimétrica que leva a afinamento corneano inferior e protrusão da córnea, não existe consenso sobre qual é o melhor caminho para adaptar lentes de contato em pacientes com ceratocone, considerando seus diferentes padrões topográficos e graus de evolução. O objetivo desse estudo é associar o grau de evolução e padrão topográfico com o tipo/desenho da lente adaptada. Métodos: Análise retrospectiva das lentes de contato adaptadas em 185 pacientes com ceratocone (325 olhos) no Departamento de Lentes de Contato. O ceratocone foi classificado de acordo com a ceratometria em graus I, II, III e IV e de acordo com a morfologia em cone redondo, oval, globoso e indeterminado. Resultados: Foram avaliados 325 olhos. Em 66,1% dos olhos com grau I foi adaptada lente monocurva. Dos 162 olhos classificados como graus I e II foram adaptadas lentes monocurva em 51%, bicurva em 30% e outros em 19%. Em relação aos olhos grau III, em 52,1% foram adaptadas lentes bicurvas e o mesmo aconteceu em 62,2% dos olhos com grau IV. Apenas 26% dos olhos grau III ou IV receberam lentes monocurva, com necessidade de bicurvas em 55%. 45% dos cones ovais foram adaptados com lentes monocurva, 35% com bicurvas e 20% com outros tipos, enquanto 55% dos cones redondos foram adaptados com lentes bicurvas, apenas 30% com monocurvas e 15% com outros desenhos. Conclusão: Lentes de contato rígida gás-permeável (LCRGP) monocurvas são mais frequentemente utilizadas em ceratocones leves e moderados e em ovais, enquanto bicurvas são mais usadas para casos graves e avançados e em cones redondos.


Assuntos
Humanos , Adolescente , Adulto , Adulto Jovem , Ajuste de Prótese/instrumentação , Lentes de Contato , Lentes de Contato Hidrofílicas , Desenho de Equipamento , Ceratocone/classificação , Acuidade Visual/fisiologia , Estudos Retrospectivos , Topografia da Córnea , Ceratocone/patologia , Ceratocone/reabilitação
3.
Arq. bras. oftalmol ; 79(1): 42-43, Jan.-Feb. 2016. graf
Artigo em Inglês | LILACS | ID: lil-771896

RESUMO

ABSTRACT Alport Syndrome is a hereditary disease that is caused by a gene mutation and affects the production of collagen in basement membranes; this condition causes hemorrhagic nephritis associated with deafness and ocular changes. The X-linked form of this disease is the most common and mainly affects males. Typical ocular findings are dot-and-fleck retinopathy, anterior lenticonus, and posterior polymorphous corneal dystrophy. Some cases involving polymorphous corneal dystrophy and corneal ectasia have been previously described. Here we present a case report of a 33-year-old female with Alport syndrome, posterior polymorphous corneal dystrophy, and irregular astigmatism, whose visual acuity improved with a rigid gas permeable contact lens.


RESUMO A síndrome de Alport é descrita como uma doença hereditária que afeta um gene relacionado à produção de colágeno das membranas basais causando nefrite hemorrágica associada com surdez e alterações oculares. A forma ligada ao X é a mais comum e afeta principalmente homens. Os achados oculares típicos são retinopatia em ponto-mancha, lenticone anterior e distrofia polimorfa posterior. Alguns casos foram descritos de associação entre a distrofia polimorfa posterior e ectasia corneana. Nós apresentamos um caso de paciente do sexo feminino, 33 anos, diagnóstico de síndrome de Alport, distrofia polimorfa posterior e astigmatismo irregular, que apresenta melhora da acuidade visual após adaptação com lentes de contato rígidas gás permeáveis.


Assuntos
Adulto , Feminino , Humanos , Lentes de Contato , Distrofias Hereditárias da Córnea/fisiopatologia , Distrofias Hereditárias da Córnea/reabilitação , Nefrite Hereditária/fisiopatologia , Ajuste de Prótese , Extração de Catarata , Topografia da Córnea , Resultado do Tratamento , Acuidade Visual
4.
Arq. bras. oftalmol ; 71(6,supl.0): 9-13, nov.-dez. 2008.
Artigo em Português | LILACS | ID: lil-507467

RESUMO

A correta manutenção das lentes de contato é fundamental para se obter sucesso e manter a continuidade de seu uso. É grande o número de pacientes que abandonam o uso de suas lentes por problemas que poderiam ser solucionados com tratamentos relativamente simples ou com uma orientação mais adequada. O mau uso das lentes, associado à má adaptação, contaminação, doenças oculares prévias e fatores ambientais, podem aumentar o número de infecções corneanas através da proliferação de microorganismos. O presente artigo visa apresentar as atualizações em relação aos cuidados e manutenção com as lentes de contato.


The proper maintenance of contact lenses is crucial for their success and to maintain the continuity of their use. Many patients abandon the use of their lenses due to problems that could be solved with relatively simple treatments. The misuse of lenses, coupled with poor adjustment, contamination, eye disease and environmental factors may increase the number of corneal infections through the proliferation of microorganisms. This article aims to provide contact lens care and maintenance updates.


Assuntos
Humanos , Lentes de Contato , Desinfecção/métodos , Ceratite/prevenção & controle , Soluções para Lentes de Contato/classificação , Soluções para Lentes de Contato/farmacologia , Lentes de Contato/microbiologia , Contaminação de Equipamentos/prevenção & controle
5.
Arq. bras. oftalmol ; 71(6,supl.0): 42-46, nov.-dez. 2008. graf, tab
Artigo em Português | LILACS | ID: lil-507473

RESUMO

OBJETIVOS: Avaliar e comparar o desempenho visual, por meio da análise de frentes de onda, de seis diferentes tipos de lentes de contato gelatinosas [Cooperflex® (Coopervision), Frequency® 55 Aspheric (Coopervision), World Vision FW® (World Vision), Pure Vision® (Bausch & Lomb), Focus® Monthly (Ciba Vision), Focus® Choice AB (Ciba Vision)]. MÉTODOS: Realizou-se estudo prospectivo em amostra constituída por 130 olhos de 71 indivíduos portadores de miopia ou hipermetropia até 6,00D e astigmatismo até 1,50D, com acuidade visual corrigida com óculos igual ou superior a 20/20. Os sujeitos foram inicialmente submetidos ao exame clínico oftalmológico e posteriormente, ao exame de análise de frentes de onda com o aberrômetro LADARWave® (Alcon), em duas condições: sem correção óptica e em uso de um dos tipos de lente de contato incluídos no estudo, com grau correspondente ao equivalente esférico do paciente e corrigido pela distância vértice. Para análise de resultados os indivíduos foram divididos em seis grupos similares, sendo testado em cada grupo um dos tipos de lente incluídos no estudo. RESULTADOS: Mudanças nos valores das aberrações de alta ordem foram verificadas durante uso das lentes de contato. De 130 olhos estudados, 78 apresentaram aumento no valor de RMS total durante o uso da lente. Os seis tipos de lente estudados demonstraram tendência ao aumento no valor médio de RMS total durante seu uso, sem diferença estatisticamente significante entre as mesmas. O estudo demonstrou tendência ao aumento no valor médio das aberrações tipo "coma" durante o uso das lentes. As lentes Frequency® Aspheric e Cooperflex® apresentaram melhor desempenho visual em relação ao "coma". O estudo demonstrou tendência à diminuição no valor médio das aberrações esféricas durante o uso das lentes, sendo esta tendência maior nos pacientes míopes em relação aos hipermétropes. Foi demonstrado tendência ao aumento no valor médio de outras aberrações de alta ordem...


PURPOSE: To evaluate the visual performance by wavefront analyses of six different kinds of soft contact lenses: Cooperflex® (Cooper Vision), Frequency® 55 Aspheric (Cooper Vision), World Vision FW® (World Vision), Pure Vision® (Bausch & Lomb), Focus® Monthly (Ciba Vision) and Focus® Choice AB (Ciba Vision). METHODS: A prospective study was performed with 130 eyes of 71 myopic or hyperopic patients with astigmatism until 1.50 diopter and best corrected visual acuity 20/20 or better. The patients first underwent ophthalmic examination and then wavefront analyses without visual correction and wearing one of the different contact lenses included in the study. The patients were divided into six similar groups, each one tested with one of the six lenses included in the study. RESULTS: Changes at the values of high order aberrations were verified during the use of contact lenses. In 78 (60 percent) of the 130 analyzed eyes an increase at the RMS (rooth mean square) values during the use of contact lens was detected. All types of analyzed contact lenses showed an increase of "coma" aberrations due to contact lens use. Frequency® Aspheric and Cooperflex® had the best visual performance in relation to "coma". There was a decrease in the medium value of spherical aberrations during the use of contact lenses, higher in myopic patients than in the hyperopic. There was an increase in the other high order aberrations (that exclude the third order "coma" and fourth order spherical aberration) characterized by the component "others" on the aberrometry examination. Focus® Choice AB had the best visual performance of this component. CONCLUSION: The use of soft contact lenses modifies the performance of high order aberrations, showing an increase of the medium values of asymmetric Zernike aberrations. This was not observed for symmetric spherical aberrations. No statistically significant differences were observed between the performance of six kinds of...


Assuntos
Adulto , Humanos , Lentes de Contato Hidrofílicas/classificação , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Análise de Variância , Topografia da Córnea/métodos , Estudos Prospectivos , Valores de Referência , Erros de Refração/reabilitação
6.
Arq. bras. oftalmol ; 71(3): 348-351, maio-jun. 2008. tab
Artigo em Português | LILACS | ID: lil-486110

RESUMO

OBJETIVO: Traçar o perfil epidemiológico de crianças encaminhadas para adaptação de lente de contato. MÉTODOS: Foi realizado estudo retrospectivo de pacientes registrados no Setor de lente de contato da Universidade Federal de São Paulo. Os pacientes com até 12 anos de idade foram avaliados quanto ao sexo, idade, diagnóstico, indicação e tipo de lente de contato testada na primeira consulta. RESULTADOS: Dos 73 prontuários avaliados, 34 (46,6 por cento) pertenciam a crianças do sexo masculino e 39 (53,4 por cento) a crianças do sexo feminino. A idade variou de 2 a 12 com média de 10,2 e desvio-padrão de 2,42 anos. O diagnóstico mais encontrado foi afacia em 16 (21,9 por cento) crianças, seguido de ceratocone em 14 (19,1 por cento), leucoma em 11 (15 por cento), anisometropia em 10 (13,7 por cento), ametropia em 9 (12,3 por cento), astigmatismo irregular em 7 (9,5 por cento) e ectopia lentis em 4 (5,4 por cento). Uma criança era alta míope (1,3 por cento) e outra emétrope (1,3 por cento) que possuía desejo de usar lente de contato estética. Em relação às indicações, 52 (71,2 por cento) pacientes tinham indicação médica, 9 (12,3 por cento) indicação óptica e 12 (16,4 por cento) indicação cosmética. Foram testadas lentes em 103 olhos sendo as mais testadas a rígida gás permeável esférica em 43 (41,7 por cento), a gelatinosa esférica em 41 (39,8 por cento) e a gelatinosa cosmética em 11 (10,6 por cento). CONCLUSÃO: O perfil epidemiológico dos usuários de lente de contato nessa faixa etária tem como diagnóstico mais prevalente a afacia, a indicação mais freqüente a de ordem médica e a lente mais testada a rígida gás permeável esférica.


PURPOSE: To describe the epidemiology of children submitted to contact lens fit. METHODS: Retrospective study of 73 children that had been submitted to contact lens fit at the "Universidade Federal de São Paulo". This study analyzed sex distribution, age, diagnosis, indications and contact lens fitted at first examination. RESULTS: 34 children (46.6 percent) were male and 39 (53.4 percent) female, aged between 2 and 12 years with mean of 10.2 and standard deviation of 2.42. The most common diagnosis was aphakia, in 16 (21.9 percent) cases. Keratoconus was present in 14 (19.1 percent), leucoma in 11 (15 percent), anisometropia in 10 (13.7 percent), refractive errors in 9 (12.3 percent), irregular astigmatism in 7 (9.5 percent), ectopia lentis in 4 (5.4 percent), high myopia in one case (1.3 percent) and one child (1.3 percent) had no ocular pathology, just wishing to change eye color. 52 (71.2 percent) had medical indication, 9 (12.3 percent) had optical indication and 12 (16.4 percent) had cosmetic indication. Contact lenses were fitted in 103 eyes, the most tested lens was rigid gas permeable in 43 (41.7 percent), soft lens in 41 (39.8 percent) and cosmetic soft lens in 11 (10.6 percent). CONCLUSION: Aphakia was the most common diagnosis among children in use of contact lens. The incidence of medical indication was higher than the others and the most tested lens was the rigid gas permeable one.


Assuntos
Criança , Pré-Escolar , Feminino , Humanos , Masculino , Afacia/epidemiologia , Lentes de Contato , Afacia/diagnóstico , Brasil/epidemiologia , Prescrições/classificação , Prescrições/estatística & dados numéricos , Ajuste de Prótese/classificação , Ajuste de Prótese/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Tempo
7.
Arq. bras. oftalmol ; 70(2): 247-254, mar.-abr. 2007. tab, graf
Artigo em Português | LILACS | ID: lil-453164

RESUMO

OBJETIVOS: Avaliar o desempenho visual e o conforto de lentes de contato de material híbrido, quanto ao apresentado por pacientes portadores de ceratocone e astigmatismo miópico composto, e comparar com a lente de contato rígida-gás-permeável nos dois grupos de pacientes. MÉTODOS: Foram submetidos à adaptação com lentes de contato 22 pacientes, sendo 8 portadores de astigmatismo miópico composto e 14 com diagnóstico de ceratocone. Entre os pacientes, 7 eram do sexo masculino e 15 do feminino, com idade média de 32,13 anos ± 8,12. Cada paciente recebeu uma lente de contato de material híbrido e, no contralateral, uma lente rígida-gás-permeável. A escolha da lente a ser adaptada no olho direito ou esquerdo foi feita aleatoriamente, sendo o trabalho duplo-mascarado. Os pacientes foram submetidos aos seguintes exames: medida do conforto por meio da escala visual analógica, tempo de ruptura do filme lacrimal, acuidade visual pela escala de Bailey-Lovie adaptada para quatro metros, sensibilidade ao contraste pelo "functional acuity contrast test" e análise das aberrações oculares pela análise de frentes de onda. RESULTADOS: Com relação ao conforto não houve associação com o tipo de lente (p=0,350). Houve variação no conforto referido ao longo do tempo até 7 dias (p=0,001), estabilizando-se após este período. A medida da acuidade visual sofreu aumento entre a adaptação e a medida obtida aos 7 dias, bem como desta para a medida de 15 dias, estabilizando-se então. A acuidade visual não apresentou diferenças com relação ao tipo de lente estudada. Verificou-se que não houve diferença no tempo de ruptura do filme lacrimal (p=0,989) com relação aos tipos de lentes, porém houve diminuição deste (p=0,001) quando comparadas as medidas antes do início do uso das lentes e com dois meses de uso. Os tipos de lentes não revelaram associação com a sensibilidade ao contraste e não diferiram das medidas feitas com o uso de óculos, exceto para a freqüência...


PURPOSE: To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS: A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was conducted. Fifteen patients were female and 7 were male, and mean age was: 32.13 ± 8.12 years. In one of the eyes a rigid-gas-permeable contact lens was adapted (DK 30), and in the other a hybrid material contact lens was adapted (DK 23). All patients were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, tear break-up time, best corrected visual acuity with the Bailey-Lovie scale adapted for 4 meters, functional acuity contrast test (FACT) and wavefront analysis. RESULTS: In relation to comfort, there was no association with the evaluated contact lens type (p=0.350). There was a variation in comfort level during the first 7 days. The visual acuity increased between the 7th and the 15th day of adaptation. Visual acuity stabilized right after this period. The visual acuity did not show differences in relation to the studied lens type. It was verified that there was no difference in the tear break-up time (p=0.989) in relation to the studied lenses type and there was a decrease in the tear break-up time (p=0.001) when we compared the measurement before the use of the lenses and 2 months after their use. There was no difference in contrast sensitivity in the used lens type and between each type and the use of glasses (p<0.047). High order aberrations decreased significantly when comparing patients with and without contact lenses, except for spherical and coma aberrations (p=0.394). CONCLUSION: Comfort and visual performance when comparing hybrid material and rigid-gas-permeable contact lenses...


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Astigmatismo/terapia , Lentes de Contato , Ceratocone/terapia , Miopia/terapia , Acuidade Visual/fisiologia , Astigmatismo/fisiopatologia , Lentes de Contato Hidrofílicas , Topografia da Córnea , Sensibilidades de Contraste/fisiologia , Métodos Epidemiológicos , Óculos , Ceratocone/fisiopatologia , Miopia/fisiopatologia , Ajuste de Prótese , Refração Ocular/fisiologia , Fatores de Tempo , Resultado do Tratamento , Lágrimas/metabolismo
8.
Arq. bras. oftalmol ; 69(4): 557-560, jul.-ago. 2006. graf, tab
Artigo em Português, Inglês | LILACS | ID: lil-435742

RESUMO

OBJETIVO: Relatar a experiência inicial com o uso de lentes de contato gelatinosas especiais para ceratocone. MÉTODOS: Estudo retrospectivo de 80 olhos de 66 pacientes usuários de lentes de contato gelatinosas especial para ceratocone, no Setor de Lentes de Contato da UNIFESP e em clínicas particulares. Os pacientes foram classificados de acordo com o grau de gravidade da doença pela avaliação ceratométrica. Foram coletados os seguintes dados: idade, sexo, diagnóstico, ceratometria, acuidade visual com a lente, equivalente esférico (ES), curvatura da lente e indicação para o seu uso. RESULTADOS: Foram estudados 80 olhos de 66 pacientes usuários de lente gelatinosa para ceratocone. A média de idade foi de 29 anos, sendo 51,5 por cento homens e 48,5 por cento de mulheres. De acordo com os grupos: incipiente: 15,0 por cento, moderado: 53,7 por cento, avançado: 26,3 por cento, grave: 5,0 por cento. A maioria dos olhos estudados (91,25 por cento) apresentou acuidade visual melhor que 20/40 com a lente. Foram adaptadas 58 por cento lentes de poder esférico (média de -5,45 dioptrias) e 41 por cento lentes com grau esferocilíndrico (variando de -0,50 a -5,00 dioptrias cilíndricas). A curva esférica mais utilizada foi de 7,6 mm (61 por cento dos olhos). As principais razões para a escolha e adaptação desta lente foram devido à intolerância e ao padrão de adaptação insatisfatório com outras lentes. CONCLUSÃO: A lente gelatinosa para ceratocone pode ser usada em casos de difícil adaptação, como uma opção para melhorar o conforto e possibilitar a reabilitação visual em pacientes que não obtiveram alternativas a não ser algum procedimento cirúrgico.


PURPOSE: To evaluate the fitting and use of a soft contact lens in keratoconic patients. METHODS: Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. RESULTS: Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5 percent were men and 48.5 percent women. According to the groups: 15.0 percent were incipient, 53.7 percent moderate, 26.3 percent advanced and 5.0 percent were severe. The majority of the eyes of patients using contact lenses (91.25 percent) achieved visual acuity better than 20/40. To 88 eyes 58 percent were tihed with lens with spherical power (mean -5.45 diopters) and 41 percent with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61 percent of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. CONCLUSION: The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Lentes de Contato Hidrofílicas , Ceratocone/terapia , Topografia da Córnea , Satisfação do Paciente , Estudos Retrospectivos , Acuidade Visual
9.
Arq. bras. oftalmol ; 69(3): 349-359, maio-jun. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-433799

RESUMO

OBJETIVO: Comparar a função visual e a resposta dos pacientes ao índice de qualidade de vida quando estes são corrigidos com óculos com lentes progressivas ou lente de contato progressiva. MÉTODOS: Foram selecionados 35 pacientes présbitas, usuários de óculos com acuidade visual igual, ou melhor, a logMAR zero (longe) e J1 (perto), para adaptarem a lente de contato Focus Progressive®. Foram comparadas medidas de acuidade visual para longe, perto e sensibilidade ao contraste com a lente de contato e com os óculos. Os resultados do questionário de avaliação de qualidade de vida NEI VFQ-25 dos mesmos pacientes corrigidos com os óculos e com a lente de contato progressiva foram comparados, levando-se em consideração o tipo de ametropia e a idade. RESULTADOS: A acuidade visual para longe, perto e a sensibilidade ao contraste foram significantemente piores com lente de contato progressiva do que com os óculos. As respostas do questionário não diferiram quanto à forma de correção quando se analisou o tipo de ametropia, entretanto foram significantemente piores com a lente de contato nos grupos míope e hipermétrope abaixo das suas respectivas medianas da idade e maiores no hipermétrope acima de sua mediana. CONCLUSÃO: As funções visuais foram significantemente piores com a lente de contato e o tipo de ametropia não influenciou nas respostas ao índice de qualidade de vida quanto à forma de correção, mas sim, quanto à idade.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Lentes de Contato/psicologia , Óculos/psicologia , Qualidade de Vida , Erros de Refração/terapia , Acuidade Visual , Fatores Etários , Inquéritos e Questionários
10.
Arq. bras. oftalmol ; 69(3): 365-370, maio-jun. 2006. tab
Artigo em Português | LILACS | ID: lil-433818

RESUMO

OBJETIVO: A prevalência do astigmatismo refracional e sua relação com a acuidade visual de resolução foram avaliados em amostra de crianças pré-verbais. MÉTODOS: Foram submetidas a exame oftalmológico 482 crianças normais com idades variando entre 2 e 36 meses. Após exclusão da amostra de 14 crianças com evidências de doenças oculares que pudessem alterar a acuidade visual, permaneceram 468 crianças (936 olhos), sendo 230 (49 por cento) do sexo masculino e 238 (51 por cento) do feminino. Todas foram submetidas a exame de acuidade visual binocular e monocular pelo procedimento do olhar preferencial através do método dos cartões de acuidade de Teller. Foi realizado em todas as crianças exame de refração sob cicloplegia e fundoscopia com oftalmoscópio indireto. RESULTADOS: O astigmatismo foi encontrado em 222 (47,43 por cento), crianças da amostra, com predomínio do tipo hipermetrópico composto e da forma a favor da regra em todas as faixas etárias. Em relação à magnitude, esta ametropia foi maior ou igual a 1,00 dioptria cilíndrica em 24,35 por cento dos sujeitos, maior ou igual a 1,00 dioptria cilíndrica em 24,35 por cento dos sujeitos, maior ou igual a 2,00 dioptrias cilíndricas em 5,55 por cento, menor que 1,00 dioptria cilíndrica em 26,92 por cento e maior ou igual a 1,00 dioptria cilíndrica e menor que 2,00 dioptrias cilíndricas em 18,73 por cento. A acuidade visual esteve dentro da faixa de normalidade em 219 crianças da amostra, independentemente da magnitude, tipo e orientação do astigmatismo. CONCLUSÃO: A acuidade visual de resolução medida pelo método dos cartões de acuidade de Teller não foi influenciada pelo astigmatismo.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Astigmatismo/epidemiologia , Seleção Visual , Acuidade Visual , Astigmatismo/diagnóstico , Brasil/epidemiologia , Técnicas de Diagnóstico Oftalmológico , Prevalência
11.
Arq. bras. oftalmol ; 68(4): 491-494, jul.-ago. 2005. tab
Artigo em Português | LILACS | ID: lil-417789

RESUMO

OBJETIVO: Estudar pacientes portadores de ceratocone numa faixa etária menor do que a usual e tentar detectar algum fator que possa influenciar no prognóstico e na evolução da doença. MÉTODOS: Foram analisados pacientes menores de 15 anos, com diagnóstico de ceratocone. Todos se submeteram a um questionário, exame ocular e ceratoscopia computadorizada. Estes pacientes foram divididos em 3 grupos e submetidos a um teste com lente de contato: 1) um grupo em que foi possível a adaptação de lente de contato; 2) um grupo em que foi indicado o transplante penetrante de córnea; 3) um grupo em que foi indicada a correção com óculos. RESULTADOS: Pacientes com acuidade visual de 20/40 ou maior, geralmente não evoluíram para transplante no período estudado. Ao contrário, pacientes com visão de 20/60 ou menor, evoluíram para transplante penetrante mais rapidamente. Ao serem estudados casos em faixa etária menor (10-15 anos), 44 por cento evoluíram para transplante. Observa-se que o ápice corneano tem localização muito variável, o que explica os diferentes níveis de dificuldade na adaptação de lentes de contato. Todos os pacientes com ápice deslocado superiormente e valores maiores que 66 D foram encaminhados para cirurgia, ao passo que olhos com valores menores que 66 D tiveram sucesso na adaptação. Nos olhos com ápice central, a adaptação foi mais fácil. Nos casos de ápice inferior não foi possível determinar um padrão para indicação de cirurgia. Nos olhos adaptados com lente de contato e curvatura menor que 51,10 D houve menos chance de evolução para transplante penetrante de córnea, quando comparados com pacientes de curvatura 57,60 ou maior. CONCLUSAO: Pacientes com curvaturas maiores que 57,40, acuidade menor que 20/60 e com idade menor de 18 anos tem uma chance maior de evoluir para transplante de córnea. Quando o ápice do ceratocone é central a adaptação de lente de contato fica mais fácil.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Lentes de Contato , Transplante de Córnea , Ceratocone/terapia , Óculos , Acuidade Visual/fisiologia , Topografia da Córnea , Ceratocone/cirurgia , Prognóstico , Estudos Prospectivos
12.
Arq. bras. oftalmol ; 68(1): 93-94, jan.-fev. 2005. tab
Artigo em Português | LILACS | ID: lil-396362

RESUMO

OBJETIVO: Avaliar a adaptação e o uso de lente de contato em pacientes que foram submetidos à cirurgia refrativa. MÉTODOS: Foi realizado estudo retrospectivo de 53 pacientes submetidos à cirurgia refrativa, que posteriormente passaram a usar lente de contato, no período de 1999 a 2003. Foram avaliados a ametropia prévia, tipo de cirurgia realizada, refração pós-cirúrgica, equivalente esférico pós-cirurgia, ceratometria pós-operatória, curva base da lente adaptada, tipo de lente de contato adaptada, acuidade visual com óculos no pós-operatório, acuidade visual final com lente de contato, complicações e motivo da interrupção do uso. O tempo de seguimento variou de 1 mês a 84 meses (média de 42,5 meses). RESULTADOS: Dos 53 pacientes analisados, 19 pacientes foram submetidos a LASIK (Laser Assisted in Situ Keratomileusis), 29 pacientes foram submetidos à RK (ceratotomia radial), 4 pacientes foram submetidos a PRK (ceratectomia fotoablativa) e em um paciente não foi possível obter o tipo de cirurgia realizado. Em 61,29 por cento dos pacientes, (57 olhos de um total de 93), foram adaptadas lentes de contato rígidas gás-permeáveis esféricas. Houve melhora da acuidade visual em 60,21 por cento dos casos (AV>20/40), com poucas complicações. CONCLUSAO: Devido ao número cada vez maior de cirurgias refrativas realizadas, espera-se que aumente o número de pacientes insatisfeitos com o resultado no pós-operatório e para os quais o uso de lentes de contato venha a ser a melhor opção. A adaptação de lentes de contato pós-cirurgia refrativa exige conhecimento e dedicação e em geral tem bons resultados principalmente pela melhora da acuidade visual.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adaptação a Desastres , Lentes de Contato , Erros de Refração/cirurgia , Acuidade Visual , Estudos Retrospectivos
13.
Arq. bras. oftalmol ; 67(6): 935-938, nov.-dez. 2004. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-393159

RESUMO

OBJETIVO: Relatar a experiência inicial com o uso de lentes de contato esclerais rígidas. MÉTODOS: Estudo retrospectivo de 13 olhos de 7 pacientes usuários de lentes de contato esclerais, no Setor de Lentes de Contato da Universidade Federal de São Paulo/Escola Paulista de Medicina. Foram coletados os seguintes dados: idade, sexo, diagnóstico, acuidades visuais inicial e final, número de horas de uso diário, complicações, queixas e o tempo de seguimento dos pacientes. RESULTADOS: Foram estudados 13 olhos de 7 pacientes portadores de lentes esclerais rígidas, sendo 11 lentes de polimetilmetacrilato e 2 de material gás-permeável. Deste total, 6 pacientes eram portadores de ceratocone e 1 paciente havia sido submetido à ceratotomia radial. Em todos os olhos estudados houve melhora da acuidade visual. Os pacientes foram estudados em média por 8 meses. CONCLUSAO: A utilização de lentes de contato esclerais pode ser uma opção na clínica de lentes de contato, propiciando melhora da acuidade visual em pacientes com ectasias corneanas ou submetidos à cirurgia refrativa, que aguardam transplante de córnea, como também, ser uma alternativa de tratamento clínico destes pacientes.


Assuntos
Criança , Adulto , Pessoa de Meia-Idade , Masculino , Feminino , Humanos , Lentes de Contato , Ceratocone/diagnóstico , Ceratotomia Radial , Lentes de Contato/efeitos adversos , Esclera , Acuidade Visual , Brasil , Estudos Retrospectivos
14.
Arq. bras. oftalmol ; 62(6): 747-9, nov.-dez. 1999. ilus
Artigo em Português | LILACS | ID: lil-279961

RESUMO

Introduçäo: Apesar da sua aparente simplicidade, o uso de lentes descartáveis deve ser feio respeitando-se os critérios de forma de uso, conservaçäo e descarte. A úlcera de córnea bacteriana é a complicaçäo mais temida em usuários de lente e pode ter relaçäo com vários fatores tais cmo higiene, conservaçäo e principalmente o uso prolongado. Objetivo: Descrever um caso e úlcera bilateral por pseudomonas em um paciente usuário de lentes descartáveis, evidenciando e discutindo a importância do exame prévio, orientaçäo e seguimento adequados, bem como ressaltando que por ser descartável a lente näo é isenta de complicaçöes graves. Relato de um caso: Um estudante de 17 anos, usando lentes descartáveis há 6 meses, sem exame ou prescriçäo médica, nos procurou queixando-se de dor em OE no qual observou-se úlcera corneana infiltrada na meia periferia. Foi colhido material e iniciado tratamento com colírios fortificados. Após 8 horas, retornou referindo agora dor em OD, tendo sido observada ceratite difusa com secreçäo mucopurulenta. A conduta foi a mesma. Os exames revelaram Pseudomonas em ambos os olhos e o quadro regrediu sem seqüelas após uma semana de tratamento. Discussäo: O autor discute os principais fatores envolvidos com o aparecimento de ceratite infecciosa em usuários de lentes de contato, lembrando que as lentes descartáveis, apesar da sua aparente simplicidade também estäo relacionadas com este grave quadro. Ressalta ainda que o uso prolongado é considerado um dos seus pricipais fatores de risco. O relato de um caso de ceratite bilateral serve de alerta para o uso deste tipo de lente sem a devida orientaçäo e acompanhamento


Assuntos
Humanos , Masculino , Adolescente , Lentes de Contato de Uso Prolongado , Infecções por Pseudomonas/diagnóstico , Úlcera da Córnea/diagnóstico , Úlcera da Córnea/etiologia
15.
Arq. bras. oftalmol ; 59(2): 205-208, abr. 1996. ilus, tab
Artigo em Português | LILACS | ID: lil-283698

RESUMO

Este estudo mostra a adaptaçäo de lentes de contato em quinze portadores de DMP, sendo que em 12 (80 por cento) a adaptaçäo ocorreu com sucesso. Adaptou-se em dez pacientes lentes de contato rígida esférica, uma paciente lente de contato tórica posterior e um paciente lente de contato gelatinosa. Três pacientes apresentaram intolerância às lentes de contato e foram submetidos a tranplante de córnea. Houve melhora da acuidade visual nos doze pacientes em que se adaptou lente de contato, sendo que todos os pacientes apresentaram no final pelo menos um olho com acuidade visual igual ou melhor que 20/40.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Lentes de Contato , Doenças da Córnea/terapia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Acuidade Visual/fisiologia
16.
Arq. bras. oftalmol ; 58(3): 149-51, jun. 1995. tab, graf
Artigo em Português | LILACS | ID: lil-260608

RESUMO

Foi realizada uma avaliação prospectiva da adaptação de lentes de contato em 86 olhos de 50 pacientes com ceratocone no Setor de Lentes de Contato da Escola Paulista de Medicina entre abril de 1991 e janeiro de 1993. A idade dos pacientes variou entre 11 e 47 anos com média de 23,54 anos; 60 por cento eram do sexo masculino; 70 por cento eram da raça branca. Não foi obtida a adaptação adequada em 6 olhos; dos outros 80 olhos ocorreram 2 casos de intolerância às lentes de contato durante o seguimento. Esses 8 casos foram indicados para transplante de córnea. A maioria dos casos era de ceratocone avançado sendo 30 olhos com ao menos um meridiano maior que 61 dioptrias. A acuidade visual melhor ou igual a 20/50 foi alcançada em 79,06 por cento do total de casos. O estudo mostra que deve se proceder a tentativa de adaptação de lentes de contato mesmo nos casos mais avançados de ceratocone pois as possibilidades de bons resultados ópticos são grandes.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Acomodação Ocular , Lentes de Contato , Ceratocone , Grupos Raciais , Transplante de Córnea , Estudos Prospectivos , Distribuição por Sexo , Acuidade Visual
17.
Arq. Inst. Penido Burnier ; 35(1): 13-6, jan. 1993. tab
Artigo em Português | LILACS | ID: lil-150552

RESUMO

As lentes de contato terapêuticas säo indicadas em uma variedade de patologias corneanas. Avaliou-se neste estudo sua eficácia, complicaçöes e tolerância em 30 pacientes com idade variável de 8 a 78 anos (média de 41), sendo 15 do sexo masculino e 15 do feminino. Desses pacientes 12 eram portadores de defeito epitelial persistente, 5 de perfuraçäo corneana tamponada por cola de cianoacrilato, 4 de ceratopatia bolhosa, 3 de suturas em córnea com pontos näo sepultados, 3 de afinamento corneano periférico e 3 de úlcera trófica meta-herpética. Todos os pacientes referiram melhora imediata da sintomatologia clínica. Quatorze pacientes evoluiram com neovascularizaçäo do leito lesado


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Doenças da Córnea/terapia , Lentes de Contato Hidrofílicas , Neovascularização da Córnea/reabilitação , Úlcera da Córnea/terapia
18.
Arq. bras. oftalmol ; 53(3): 123-5, 1990. ilus
Artigo em Português | LILACS | ID: lil-94792

RESUMO

Ceratite intersticial näo sifilítica com sintomas vestíbulo-auditivos (Sindrome de Cogan) é uma entidade clínica rara. Os autores descrevem um caso de uma paciente feminina de 34 anos de idade que apresentou sinais e sintomas vestíbulo-auditivos característicos da doenäa e manifestaçöes oculares atípicas. O quadro corneano era de opacidade estromal anelar bilateral por possíveis depósitos de colesterol e no fundo do olho, observava-se edema de papila bilateral durante a evoluçäo.


Assuntos
Humanos , Feminino , Adulto , Ceratite/etiologia , Manifestações Oculares/diagnóstico , Brasil , Ceratite/diagnóstico
19.
Arq. bras. oftalmol ; 53(1): 41-4, 1990. ilus, tab
Artigo em Português | LILACS | ID: lil-117577

RESUMO

Os autores revisaram a adaptaçäo de lentes de contato em 40 olhos de 35 pacientes submetidos a transplante penetrante de córnea, com tempo médio de seguimento de 33,8 meses. A principal indicaçäo do transplante nesta série foi o ceratocone (65,0%). O astigmatismo pós-operatório variou de 0,50 a 12,75 dioptrias (média = 4,75 dioptrias). Em 55% dos pacientes, a acuidade visual foi de 20/40 ou melhor, após a adaptaçäo. As curvas-base das lentes de contato adaptadas foram, em média, 2,65 dioptrias mais curvas que o meridiano mais plano da córnea, e o diâmetro médio foi de 8,7 mm. 32 lentes adaptadas (86,5%) foram rígidas (22 gás-permeáveis e 10 acrílicas). O sucesso na adaptaçäo ocorreu em 46% dos casos. Os insucessos foram devidos à instabilidade excessiva da lente (8 casos), rejeiçäo do transplante (3 casos) e intolerância à lente de contato (2 casos)


Assuntos
Masculino , Feminino , Adulto , Astigmatismo/reabilitação , Lentes de Contato/efeitos adversos , Transplante de Córnea/história , Brasil
20.
An. oftalmol ; 8(1): 77-9, abr. 1989. ilus
Artigo em Português | LILACS | ID: lil-89128

RESUMO

Os parâmetros básicos envolvidos na adaptaçäo de lentes de contacto rígidas säo discutidos. O autor demosntra a importância das relaçöes entre a curva corneana e a curva básica da lente de contacto, produzindo meniscos de filme lacrimal que alteram o valor dióptrico da adaptaçäo


Assuntos
Lentes de Contato , Terminologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA